Metric fitting results
Metric "HDR-VDP-2.0"Test set "Complex images"
R = 5 dB
chi_2_red = 2.5

See the gallery of stimuli.
About the data set "Complex images"
Distortions in complex images
This data set was measured for comprehensive testing of visual
models using actual distortions and complex images. The distortions
are white-noise, JPEG compression artifacts, bilinear upsampling
(blurring), and sine-gratings. All distortions are restricted to a
small image regions to simplify the measurements.
The thresholds were measured in the 4-alternative-forced-choice
experiment, in which all four images were shown side-by-side. The
measurement procedure was the same as for the "Contrast sensitivity
for wide luminance range" data set.
About the metric "HDR-VDP-2.0"
This is the proposed metric described in
detail in the paper "HDR-VDP-2: A calibrated visual metric for
visibility and quality predictions in all luminance conditions" (doi). It shares
many similarities with VDP'93 and HDR-VDP, as it was inspired by these
metrics, but the functionality is much extended and individual
components are thoroughly revised. The major differences are:
- The metric predicts both visibility (detection/decrimination)
and image quality (mean-opinion-score).
- The metric is based on new CSF measurements, made in the
consistent viewing conditions for a large range of luminance and
frequency.
- The new metric models L-, M-, S- and rod sensitivities and is
sensitive to different spectral characteristic of the incoming
light.
- Photoreceptor light sensitivity is modelled separately for cones
and rods, though L and M cones share the same characteristic.
- The intra-ocular light scatter function (glare) has been fitted
to the experimental data.
- The model used a steerable pyramid rather than cortex transform
to decompose image into spatially- and orientation-selective
bands. Steerable filter introduces less ringing and in general case
is computationally more efficient.
- The new model of contrast masking introduces inter-band masking
and the effect of CSF flattening.
- A simple spatial-integration formula using probability summation
is used to account for the effect of stimuli size.