HDR-VDP-2: Calibration parameters

This is a complete list of HDR-VDP-2 parameters that were found by fitting the visual model to several contrast detection test sets. Refer to the paper for a detailed explanation.

The suggested model parameters may be periodically updated. For the latest set of parameter values, refer to the HDR-VDP-2 web-site.

This is the result of calibration made on 30 Aug 2011

MTF - modullation transfer function of the eye

kakbk
10.4248390.028
20.5724350.37
30.00016757637
40.00255872360

CSF - (neural) contrast sensivitity function

Adapting luminance La [cd/m2]p1p2p3p4
0.0020.9912653.740380.507224.46044
0.020.8008893.541040.6825054.94958
0.20.4765054.374530.7503155.28678
20.4057824.406020.9353145.61425
200.3342783.795421.073276.4635
1500.3945332.77551.165777.45665

sA - joint luminance sensitivity

p5p6p7p8
30.1624.06271.65960.2712

Neural noise - contrast masking - psychometric function

pqkselfkxokxnβ
3.53.131551.545492.8131933.50581

Image quality - spatial frequency band weighting

Spatial frequency [cpd]Weight wf
150.2963
7.50.2111
3.750.1737
1.8750.0581
0.9375-0.028
0.46880.0586
0.23440.2302

Image quality - logistic function

q1q2
4.4460.8994